The turbine meter and the orifice meter are commonly used
inferential meters for liquid measurement. Technical Data used in the field
explained in diploma in petroleum technology. These meters
indirectly determine volume by sensing some property of the moving stream that
can be related to volume. For example, the rotation of the turbine blades in
the turbine meter and the differential pressure developed across the orifice
plate in an orifice meter can be used as basis of volume determination.
Turbine meters became important in volume measurement when
electronics were accepted as an element of a measuring device. The rotation of
the turbine blades can be sensed electronically without need for any mechanical
connection to the turbine rotor. This provides a simple arrangement that is
inherently reliable and particularly suitable for high-pressure service. Thus,
turbine meters initially were applied to measure injection water volumes.
However, high-viscosity fluids drastically reduce the range of turbine meters.
Turbine meters are being used for well testing and wetoil
lease production measurements when combined with net-oil computers.
These meters tend to be more tolerant of short over-range periods and sandy
fluid than are positive volume meters. Turbine meters also arc being used for
ACT, particularly for high-volume and/or high-pressure service. Some more
details of diploma
in petroleum technology are as under.
Orifice meters are used more commonly for gas measurement
but they have some applications in liquid measurement. Compressible liquids
that require pressure correction for volume determination frequently are
measured with orifice meters.
The primary device for lease gas volume measurement has been
and continues to be the orifice meter, which initially measured gas volume by
using a mercury manometer before development of the bellows-type chart
recorder. Orifice meters have these advantages: (1) no moving parts in the gas
stream, (2) the ability to handle wide range of flow rates (long term) by means
of plate size changes, (3) reliable and no external powered recorder, and (4) a
reliable sensor (bellows). The chart recorder is not compatible with automatic
data acquisition; other types of gas measurement devices are used with SCADA.
These gas measurement devices include positive-displacement meters, gas-flow
computers, turbine meters, and vortex meters. TSK Training for Skills and
Knowledge is the best institute in Rawalpindi Islamabad for Pakistani Students
who wants to join diploma in petroleum engineering.